Female, 52 years old The medical-damage appraisal committee has confirmed the following sequence of events in writing On the morning of 29 January at 09:11 the patient presented to the gynecology outpatient clinic because of “menopause for two years, requesting IUD removal.” Certain preoperative examinations were performed. At approximately 10:50 on the morning of 30 January the IUD was removed in the gynecology outpatient clinic. At approximately 11:20 after the procedure the patient complained of lower-abdominal pain accompanied by vomiting. Thereafter she remained under observation in the abortion suite. At 15:15 a complete-blood-count specimen was collected; the result issued at 15:21 showed a white-blood-cell count of 21.27 × 10⁹/L. At 15:27 ultrasonography indicated: intrauterine fluid collection 0.2 cm, pelvic fluid and pus collection depth 2.9 cm; the patient complained of abdominal pain and distension; outpatient catheterization was performed and clear urine flowed freely. At 16:40 catheterization was repeated on the ward; no appreciable fluid was obtained. At approximately 17:20 the patient left the hospital to continue observation at home. At approximately 01:31 on 31 January she was brought by family members to the emergency department. A surgical physician examined her and took the history; at approximately 01:50 an internal-medicine physician joined the evaluation: the patient was lethargic, blood pressure unobtainable, pulse weak, extremities cold, heart rate 160 beats/min. Consciousness progressively deteriorated; at 02:13 the electrocardiogram showed a flat line; death was declared at 04:17. ********** The following is an ultrasound examination report Examination time: 31 January Department: Emergency Clinical diagnosis: vomiting Examination sites: [uterus and adnexa, trans-abdominal] [bedside ultrasound] [liver, gallbladder, spleen, pancreas, kidneys] [intraperitoneal fluid] Ultrasound findings: Liver: normal size and shape, smooth surface, homogeneous parenchymal echoes, vessels clearly displayed, portal vein and intrahepatic bile ducts not dilated; CDFI shows good portal-vein filling with hepatopetal red flow. Status post cholecystectomy; common bile duct not appreciably dilated. Spleen: normal size and shape, homogeneous echoes, splenic-vein not dilated. Pancreas poorly visualized because of intervening gas. Both kidneys normal in size and shape with clear architecture; collecting systems not separated; no definite stone echoes; CDFI shows good arborizing flow signals within both kidneys. Free fluid is present around the liver, in the hepatorenal space and around the spleen, deepest approximately 16 mm, with suboptimal internal transmission. Ultrasound impression: Intraperitoneal fluid Report time: 04:21:25 on 31 January (by which time the patient had already died) ********** The final appraisal opinion of the medical-damage appraisal committee is as follows The hospital committed the following faults 1. Violation of the technical norms governing removal of an intrauterine device after menopause 2. Failure to establish a timely diagnosis and to institute appropriate treatment when the patient developed severe abdominal pain and vomiting half an hour after the procedure 3. Postoperative perforation of the uterus and small intestine resulting in: tissue necrosis at the sites of uterine and small-intestinal perforation, diffuse peritonitis with pelvic pus and fluid collection; acute pulmonary congestion and edema, cerebral edema.
SI

This case represents a tragic sequence of events stemming from a recognized procedural complication of intrauterine device (IUD) removal in a postmenopausal patient, compounded by a failure to recognize and act upon early signs of visceral injury and peritonitis.

In a postmenopausal individual, uterine atrophy, cervical stenosis, and altered tissue compliance significantly increase the technical difficulty and risk of uterine perforation during endouterine procedures. Within thirty minutes of the IUD removal, the patient developed classic symptoms of visceral trauma, specifically acute lower abdominal pain and severe vomiting. The subsequent laboratory and imaging findings obtained that afternoon—a severely elevated white blood cell count of 21.27 × 10⁹/L alongside pelvic fluid and pus collection on ultrasound—were clear clinical indicators of an intra-abdominal catastrophe, namely uterine perforation with concurrent bowel damage and contamination of the peritoneal cavity.

Despite these critical red flags, the opportunity for timely surgical intervention was missed, and the patient left the facility. The continuous leakage of bowel contents into the peritoneal cavity led to rapid tissue necrosis, diffuse peritonitis, and fulminant sepsis. By the time the patient returned to the emergency department early the following morning, she had progressed to uncompensated septic shock, manifested by altered consciousness, unmeasurable blood pressure, profound tachycardia, and peripheral hypoperfusion, ultimately leading to irreversible cardiac arrest and secondary organ edema.

From the perspective of SI independent review, the key points of evaluation center on the failure to adhere to safety protocols for postmenopausal IUD extractions and the catastrophic delay in responding to acute post-procedural complications. When a patient exhibits acute abdominal pain, vomiting, extreme leukocytosis, and sonographic evidence of pelvic fluid or pus immediately following an intrauterine procedure, immediate surgical evaluation, advanced imaging, or emergency exploratory intervention is mandatory. SI review aligns with the appraisal committee's conclusion that the failure to establish an early diagnosis of uterine and intestinal perforation directly resulted in overwhelming sepsis, peritonitis, and the patient's death.

Med3rd
The technical norms governing removal of an intrauterine device in a postmenopausal woman are entirely distinct from those applicable to a woman of reproductive age; the two sets of standards are independent of each other.
SI

SI review confirms that postmenopausal IUD removal requires a completely distinct clinical protocol compared to removal during the reproductive years.

In women of reproductive age, the cervix is typically pliable and the uterine wall maintains normal thickness and elasticity, usually allowing for a straightforward, routine extraction. In contrast, postmenopausal status leads to significant estrogen depletion, resulting in uterine atrophy, thinning and fragility of the myometrium, and severe cervical stenosis or canal obliteration. The device itself may also become deeply embedded or impacted within the thinned uterine wall over time.

Because of these distinct physiological changes, the technical norms for postmenopausal IUD removal dictate specific precautions that are not required for reproductive-age patients. Standard postmenopausal protocols often necessitate preoperative cervical priming or softening agents, careful pre-procedural assessment of uterine size and axial position, adequate analgesia or anesthesia to prevent reflexive muscle spasm, and the use of specialized, delicate instruments under direct visualization or ultrasound guidance. Standard traction without proper cervical dilation or localized visualization carries a high risk of uterine structural failure.

An independent SI reviewer would examine whether the medical team recognized the unique physiological risks of the postmenopausal state and adhered to these specialized technical norms prior to and during the procedure. The application of standard reproductive-age extraction techniques to an atrophic, postmenopausal uterus represents a fundamental breach of specialized care norms, directly contributing to mechanical perforation of the uterus and adjacent abdominal viscera.

⌕