Med3rdChecksIt
Med3rd
Female, 82 years old Clinic Record Department: Cardiac Surgery 16 June, 15:23 Chief complaint: Follow-up of ascending-aortic dilatation History of present illness: The patient experienced chest tightness and discomfort and sought evaluation. Echocardiography showed: 1. bicuspid aortic valve with calcification and mild stenosis, aneurysmal dilatation of the ascending aorta; 2. basal septal hypertrophy Physical examination: heart rate bpm, rhythm , general condition fair. Outpatient diagnosis: ascending-aortic dilatation Management: 1. Periodic follow-up 2. Investigations 3. Medication plan Print time: 16 June, 15:33 ********** Echocardiographic Diagnostic Report (Cardiac color-Doppler ultrasound + left-ventricular function + tissue Doppler) Parasternal long-axis; parasternal short-axis; apical views I. M-mode and flow-Doppler measurements: / mmHg (H (cm): / W (kg): / BSA: /) Item Measured value Normal range Aortic-root diameter 36 (23–36 mm) Left-atrial diameter 33 (23–39 mm) Left-ventricular end-diastolic diameter 45 (37–54 mm) Left-ventricular end-systolic diameter 28 (21–35 mm) Interventricular septal thickness 12 (6–11 mm) Left-ventricular posterior-wall thickness 11 (6–11 mm) Pulmonary-artery systolic pressure 32 (<40 mmHg) II. Left-ventricular function and tissue-Doppler measurements Left-ventricular ejection fraction (LVEF): 68 % Mitral inflow: biphasic E and A, E/A <0.8; DT 210 ms Tissue Doppler: S-wave peak 8 cm/s; e'/a' <1 III. Two-dimensional echocardiography and flow imaging of the chambers and great vessels: 1. Left-atrial diameter normal, left-ventricular diameter normal, basal septum thickened, remaining left-ventricular wall thickness normal, left-ventricular outflow tract unremarkable, segmental wall motion normal. 2. Mitral leaflets not thickened, opening unrestricted, orifice area within normal limits, closure morphology normal; color Doppler shows trivial mitral regurgitation. 3. Aortic sinus not dilated; ascending aorta aneurysmal at 53 mm; aortic valve bicuspid with horizontal cleft and a ridge at the left–right coronary commissure, leaflets calcified, opening mildly restricted; continuous-wave peak velocity 2.8 m/s, peak gradient 28 mmHg, mean gradient 16 mmHg; color Doppler shows trivial aortic regurgitation. 4. Inferior vena cava diameter normal; right-heart chambers free of abnormal echoes; interatrial septum intact, no atrial-level shunt on color Doppler. Right-atrial diameter normal, right-ventricular basal diameter normal, right-ventricular outflow-tract diameter normal, right-ventricular wall thickness normal, right-ventricular systolic function normal, TAPSE normal. Pulmonary artery not dilated, pulmonary valve not thickened, opening unrestricted; mean pulmonary pressure not obtained; tricuspid leaflets not thickened, opening unrestricted, closure morphology normal; color Doppler shows trivial tricuspid regurgitation. 5. No definite pericardial effusion. IV. Conclusion: Outpatient diagnosis: Bicuspid aortic valve with calcification and mild stenosis, aneurysmal dilatation of the ascending aorta; basal septal hypertrophy Examination time: 16 June, 14:14:37 Review time: 16 June, 14:24:57 ********** Informed-Consent Form for Implantable Medical Devices 11 September, 16:05 Admission diagnosis: ascending aortic aneurysm; congenital bicuspid aortic valve; cardiac function class III During treatment the following medical implants will be required: prosthetic vascular graft, wires, etc. The attending physician has explained the matter clearly to the patient and family; they understand and agree to implantation of the devices. Patient’s opinion (“agree” or “disagree”): agree disagree ********** 11 September, 16:01 Surgical Consent Form Name of proxy: (omitted) Relationship to patient: husband Discussion record: 1. Patient’s diagnosis: ascending aortic aneurysm; congenital bicuspid aortic valve; cardiac function class III 2. Surgical indications: ascending aortic aneurysm, congenital bicuspid aortic valve, cardiac function class III 3. Proposed operation: partial resection of the ascending aorta with prosthetic graft replacement + partial aortic-arch prosthetic graft replacement + transesophageal echocardiography + open-heart surgery with cardiopulmonary bypass + open-heart surgery under hypothermia (systemic) 4. Proposed anesthesia: general 5. Operative risks and complications: possible intra- and postoperative complications and risks: 1. anesthetic accident; 2. cardiopulmonary-bypass accident (thrombo-embolism, air embolism, machine malfunction, etc.); 3. intra- or postoperative major hemorrhage, cardiac tamponade, re-exploration for bleeding, uncontrolled bleeding, etc.; 4. difficulty in weaning from bypass, low-cardiac-output syndrome, or cardiac arrest that cannot be resuscitated; 5. electrolyte imbalance, arrhythmia; 6. organ or limb embolism and gangrene caused by thrombus, air or other factors; 7. postoperative failure of major organs (heart, lung, brain, liver, kidney); 8. prolonged ventilator dependence with pulmonary complications or tracheostomy, inability to wean; 9. injury to the conduction system requiring permanent pacemaker; 10. paravalvular leak (possible reoperation or valve replacement); 11. residual shunt; 12. residual murmur; 13. dysfunction after valve repair or of a prosthetic valve; 14. re-occlusion after coronary bypass, perioperative myocardial infarction, aortic dissection after bypass; 15. infection (endocarditis, wound infection, sternal dehiscence, pneumonia, urinary-tract infection, etc.); 16. other complications (upper-gastrointestinal bleeding, puncture-site bleeding, hemopneumothorax, hoarseness); 17. complications of postoperative anticoagulation (bleeding, thrombosis, etc.). 6. Alternative treatment: medical pharmacologic therapy If the patient or proxy does not understand the above risks and complications, further explanation may be requested from the physician. After full understanding the patient or proxy decides independently whether to proceed with surgery or to choose the alternative. Please state the decision in writing and sign this document. ********** Echocardiographic Diagnostic Report Instrument: portable echocardiography Examination: () Intraoperative transesophageal echocardiography and three-dimensional echocardiography I. Echocardiographic findings: (acoustic window: good) Preoperative transesophageal study: 1. Left-atrial diameter normal, left-ventricular diameter normal, basal septum thickened, remaining left-ventricular wall thickness normal, left-ventricular outflow tract unremarkable, segmental wall motion normal. 2. Mitral leaflets not thickened, opening unrestricted, orifice area within normal limits, closure morphology normal; color Doppler shows trivial mitral regurgitation. 3. Aortic sinus not dilated; ascending aorta aneurysmal at 53 mm; aortic valve bicuspid with horizontal cleft and a ridge at the left–right coronary commissure, leaflets calcified, opening mildly restricted; continuous-wave peak velocity 2.8 m/s, peak gradient 28 mmHg, mean gradient 16 mmHg; color Doppler shows trivial aortic regurgitation. 4. Inferior vena cava diameter normal; right-heart chambers free of abnormal echoes; interatrial septum intact, no atrial-level shunt. Right-atrial diameter normal, right-ventricular basal diameter normal, right-ventricular outflow-tract diameter normal, right-ventricular wall thickness normal, right-ventricular systolic function normal, TAPSE normal. Pulmonary artery not dilated, pulmonary valve not thickened, opening unrestricted; color Doppler shows trivial pulmonary regurgitation; tricuspid leaflets not thickened, opening unrestricted, closure morphology normal; color Doppler shows trivial tricuspid regurgitation. 5. No definite pericardial effusion. Intraoperative transesophageal study: After ascending-aortic replacement the prosthetic graft appears normal; the aortic valve remains bicuspid with a horizontal cleft and left–right commissural ridge, leaflets thickened, opening mildly restricted; continuous-wave peak gradient 11 mmHg, mean gradient 7 mmHg; closure morphology normal; color Doppler shows trivial aortic regurgitation. II. Conclusion: Intraoperative transesophageal study: (preoperative) bicuspid aortic valve with calcification and mild stenosis, aneurysmal dilatation of the ascending aorta; (postoperative) status after ascending-aortic replacement, no abnormality (Report for reference only; clinical correlation required) Examination time: 12 September, 16:40:34 Review time: 12 September, 16:40:34 ********** Radiologic Diagnostic Report (X-ray) Department: Cardiac Surgery Clinical diagnosis: Ascending aortic aneurysm; congenital bicuspid aortic valve; cardiac function class III Request: postoperative review Examination time: 14 September, 13:23:55 Report dictation time: 15 September, 09:10:18 Report review time: 15 September, 10:30:20 Site and name: chest Method: anteroposterior chest radiograph Findings: Status post cardiac surgery; dense suture material in the sternal region; increased lung markings; scattered linear and patchy opacities in both lungs; cardiac silhouette mildly enlarged; mediastinum slightly widened; both diaphragmatic surfaces smooth; both costophrenic angles blunt. Diagnosis: (bedside) postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions, overall comparable to the film of 13 September, follow-up; cardiac silhouette mildly enlarged—correlate with echocardiography. ********** Radiologic Diagnostic Report (X-ray) Department: Cardiac Surgery Clinical diagnosis: ascending aortic aneurysm; congenital bicuspid aortic valve; cardiac function class III Request: assist Examination time: 13 September, 13:25:25 Report dictation time: 13 September, 16:33:03 Report review time: 15 September, 08:38:51 Site and name: chest Method: anteroposterior chest radiograph Findings: Status post cardiac surgery; dense suture material in the sternal region; increased lung markings; scattered linear and patchy opacities in both lungs; cardiac silhouette mildly enlarged; mediastinum slightly widened; both diaphragmatic surfaces smooth; both costophrenic angles blunt. Diagnosis: postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions, follow-up; cardiac silhouette mildly enlarged—correlate with echocardiography. ********** Department: Cardiac Surgery Clinical diagnosis: ascending aortic aneurysm; congenital bicuspid aortic valve; cardiac function class III Request: assist Examination time: 15 September, 13:51:41 Report dictation time: 15 September, 14:55:23 Report review time: 16 September, 07:55:56 Site and name: chest Method: anteroposterior chest radiograph Findings: Status post cardiac surgery; dense suture material in the sternal region; increased lung markings; scattered linear and patchy opacities in both lungs; cardiac silhouette mildly enlarged; mediastinum slightly widened; both diaphragmatic surfaces smooth; both costophrenic angles blunt. Diagnosis: (bedside) postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions, follow-up; cardiac silhouette mildly enlarged—correlate with echocardiography. ********** Pathology Diagnostic Report Department: Cardiac Surgery Pathology number: Material submitted: Received: 13 September, 07:47:27 Review time: 17 September, 13:09:23 Gross: (ascending-aortic wall tissue) wall-like specimen measuring 3.8 × 1.4 cm, wall thickness 0.2 cm. Diagnosis: (ascending-aortic wall tissue) elastic arterial wall with mild medial myxoid degeneration; otherwise unremarkable. Sampling site: ********** Radiologic Diagnostic Report (X-ray) Department: Cardiac Surgery Clinical diagnosis: status after partial ascending-aortic and partial aortic-arch prosthetic graft replacement—postoperative review Request: postoperative review Examination time: 18 September, 09:00:35 Report dictation time: 18 September, 09:15:35 Report review time: 18 September, 11:20:32 Site and name: chest Method: anteroposterior chest radiograph Findings: Status post cardiac surgery; dense suture material in the sternal region; increased lung markings; scattered linear and patchy opacities in both lungs; cardiac silhouette mildly enlarged; mediastinum slightly widened; both diaphragmatic surfaces smooth; both costophrenic angles blunt. Diagnosis: Postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions; cardiac silhouette mildly enlarged—correlate with echocardiography. ********** Echocardiographic Diagnostic Report (Cardiac color-Doppler ultrasound + left-ventricular function + tissue Doppler) Parasternal long-axis; parasternal short-axis; apical views; acoustic window: poor I. Two-dimensional and Doppler measurements: / mmHg (H (cm): 152 W (kg): / BSA: /) Item Measured value Normal range Aortic-root diameter 33 (23–36 mm) Left-atrial diameter 39 (23–39 mm) Left-ventricular end-diastolic diameter 47 (37–54 mm) Left-ventricular end-systolic diameter 30 (21–35 mm) Interventricular septal thickness 11 (6–11 mm) Left-ventricular posterior-wall thickness 10 (6–11 mm) Pulmonary-artery systolic pressure 21 (<40 mmHg) II. Left-ventricular function and tissue-Doppler measurements: Left-ventricular ejection fraction (LVEF): 66 % Mitral inflow: uniphasic, irregular rhythm, E/A / 0.8; DT: / ms Tissue Doppler: S-wave peak 5 cm/s; e'/a' / 1 III. Two-dimensional echocardiography and flow imaging: 1. Left-atrial diameter normal, left-ventricular diameter normal, left-ventricular wall thickness normal, left-ventricular outflow tract unremarkable, segmental wall motion normal. 2. Mitral leaflets not thickened, opening unrestricted, orifice area within normal limits, closure morphology normal; color Doppler detects no mitral regurgitation. 3. Aortic sinus not dilated; status after ascending-aortic prosthetic graft (internal diameter 30 mm) replacement, no abnormality; aortic valve remains bicuspid with a horizontal cleft and pointed left–right coronary commissure, leaflets calcified, opening unrestricted; color Doppler shows trivial aortic regurgitation. 4. Inferior vena cava diameter normal; right-heart chambers free of abnormal echoes; interatrial septum intact, no atrial-level shunt. Right-atrial diameter normal, right-ventricular basal diameter normal, right-ventricular outflow-tract diameter normal, right-ventricular wall thickness normal, right-ventricular systolic function normal, TAPSE normal. Pulmonary artery not dilated, pulmonary valve not thickened, opening unrestricted; mean pulmonary pressure not obtained; tricuspid leaflets not thickened, opening unrestricted, closure morphology normal; color Doppler shows trivial tricuspid regurgitation. 5. No definite pericardial effusion. IV. Conclusion: 1. Status after ascending-aortic replacement, no abnormality 2. Bicuspid aortic-valve deformity (Report for reference only; clinical correlation required) Examination time: 18 September, 09:05:36 Review time: 18 September, 09:11:01 ********** Discharge Summary Department: Cardiac Surgery Admission date: 10 September Discharge date: 20 September Outpatient diagnosis: ascending aortic aneurysm; congenital bicuspid aortic valve; cardiac function class III; hyperlipidemia Admission diagnosis: ascending aortic aneurysm; congenital bicuspid aortic valve; cardiac function class III; hyperlipidemia Discharge diagnosis: status after vascular graft replacement Admission status (main symptoms and signs): Ascending-aortic dilatation discovered on physical examination five years earlier. Chest wall normal; lungs clear to percussion. No apical prominence, normal apical impulse, no thrill, no friction rub, no heave; no subxiphoid heave; impulse not diffuse. Heart rate 76 beats/min, regular. No water-hammer pulse, no pistol-shot sound, no peripheral capillary pulsation. Pathology diagnosis: (ascending-aortic wall tissue) elastic arterial wall with mild medial myxoid degeneration; otherwise unremarkable. Investigation results: Urinalysis (11 September): leukocyte esterase +. Electrolytes (16 September): ionized calcium 1.10; phosphorus 0.79 mmol/L. Blood-gas analysis (18 September): carbon dioxide 22 mmol/L; oxygen saturation 99.2 %; partial pressure of oxygen 203.00. Complete blood count (18 September): white-cell count 13.96 × 10⁹/L; monocyte count 1.17 × 10⁹/L; lymphocyte percentage 15.0 %; basophil count 0.10 × 10⁹/L; neutrophil count 10.3 × 10⁹/L; total hemoglobin 113.4 g/L. Cardiac markers (18 September): NT-proBNP 887.0 pg/mL. Cardiac markers (18 September): cardiac troponin T 0.038 ng/mL. Renal function (18 September): urea 13.5 mmol/L. Liver function (18 September): γ-glutamyltransferase 78 U/L; lactate dehydrogenase 333 U/L; total bilirubin 21.2 µmol/L. Coagulation (19 September): INR 2.94; prothrombin time 34.5 s; prothrombin-time ratio 2.85; D-dimer 2.10 mg/L; activated partial thromboplastin time 42.4 s; fibrinogen 696 mg/dL; activated partial thromboplastin time 24.3 s. Special investigations and main consultations: Abdominal aortic CTA (13 August): abdominal aortic atherosclerosis; common origin of the celiac trunk and superior mesenteric artery; mild plaque and luminal narrowing at the proximal celiac and superior mesenteric arteries; hiatal hernia. Thoracic aortic CTA (13 August): ascending aortic aneurysm; thoracic aortic atherosclerosis. Non-contrast chest CT (11 September): tiny chronic inflammatory nodule in the right lung, annual follow-up; scattered chronic inflammatory and residual foci in both lungs, follow-up; aneurysmal dilatation of the ascending aorta—clinical correlation; hiatal hernia. Non-contrast cranial CT (11 September): multiple lacunar foci, aging brain; MR if necessary. Routine electrocardiogram (11 September): sinus rhythm; ST-segment change (horizontal depression 0.5 mm in V4–V6); T-wave change (flat, low upright or biphasic in II, III, aVF, V4–V6). Intraoperative (two-dimensional) transesophageal echocardiography (12 September): (preoperative) bicuspid aortic valve with calcification and mild stenosis, aneurysmal dilatation of the ascending aorta; (postoperative) status after ascending-aortic replacement, no abnormality. Chest radiograph (13 September): postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions, follow-up; cardiac silhouette mildly enlarged—correlate with echocardiography. Chest radiograph (15 September): (bedside) postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions, overall comparable to the film of 13 September, follow-up; cardiac silhouette mildly enlarged—correlate with echocardiography. Chest radiograph (15 September): (bedside) postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions, follow-up; cardiac silhouette mildly enlarged—correlate with echocardiography. Chest radiograph (18 September): postoperative cardiac changes, pulmonary infiltrates, small bilateral pleural effusions; cardiac silhouette mildly enlarged—correlate with echocardiography. Routine echocardiography (cardiac color-Doppler + left-ventricular function + tissue Doppler) (18 September): 1. status after ascending-aortic replacement, no abnormality 2. bicuspid aortic-valve deformity. Routine electrocardiogram (18 September): sinus rhythm; T-wave change (flat, biphasic or shallowly inverted in leads with dominant R waves). Course of diagnosis and treatment (operative name, date, transfusion volume, detailed pathology, wound healing and other): Operative date: 12 September Intraoperative diagnosis: ascending aortic aneurysm, congenital bicuspid aortic valve, cardiac function class III Operative name: partial resection of the ascending aorta with prosthetic graft replacement, partial aortic-arch prosthetic graft replacement, transesophageal echocardiography, open-heart surgery with cardiopulmonary bypass, open-heart surgery under hypothermia (systemic) Wound information: grade I / A Operative course: (1) The patient was placed supine; after anesthesia and heparinization a conventional median sternotomy was performed, peripheral vessels were exposed and cardiopulmonary bypass was established. (2) Exploration showed the ascending aorta to measure 54 mm in diameter with dilatation along the greater curvature. An H-shaped aortotomy was made. A 30 mm Gelweave straight graft was used to replace the diseased ascending aorta; the proximal anastomosis was performed with continuous 4-0 Prolene at the sinotubular junction and reinforced with pledgets inside and outside the graft; the distal anastomosis was performed with continuous 4-0 Prolene at the level of the origin of the innominate artery and likewise reinforced with pledgets; the native diseased ascending aorta was wrapped around the graft with continuous 4-0 Prolene. Distal open anastomosis was performed under deep hypothermic circulatory arrest for 13 minutes with selective cerebral perfusion via the innominate artery. Operative date: 12 September Intraoperative diagnosis: ascending aortic aneurysm, congenital bicuspid aortic valve, cardiac function class III Anesthesia: local Procedure: coronary angiography Brief course: Coronary angiography: a 5 F Tig catheter was advanced to the left coronary ostium; the circulation was right-dominant. Left main stem free of stenosis. Left anterior descending free of stenosis. First diagonal free of stenosis. Circumflex free of stenosis. First obtuse marginal free of stenosis. The catheter was advanced to the right coronary ostium; proximal right coronary artery showed a focal 30 % stenosis, mid-right coronary artery a focal 40 % stenosis. Posterior left-ventricular branch free of stenosis. Posterior descending free of stenosis. Condition at discharge and discharge instructions (medications and advice): The patient is conscious, vital signs stable. Lungs clear; heart rate 90 bpm, regular, no murmur. No lower-extremity edema; dorsalis-pedis pulses normal. Discharge medications: Torasemide tablets, once daily, 5 mg (for one month) Metoprolol succinate sustained-release tablets, once daily, 0.5 tablet (for one month) Pentoxyverine tablets, three times daily, one tablet (for one month) Warfarin sodium tablets, once daily, 1.5 mg (for four months; thereafter decide whether to continue anticoagulation according to follow-up results; monitor prothrombin time regularly and maintain INR between 2.0 and 3.0) Anaprazole sodium enteric-coated tablets, once daily, 20 mg (until finished) Urapidil sustained-release capsules, once daily, 30 mg (until finished; monitor blood pressure) Discharge precautions: Keep the wound dry and clean; have sutures removed two weeks postoperatively at the rehabilitation facility Avoid vigorous upper-limb exertion for six months; do not lift more than 10 kg Perform rehabilitation exercises according to personal functional capacity Last INR before discharge was 2.94, corresponding to a warfarin dose of 1.5 mg; target INR range 2.0–3.0. Take warfarin regularly according to medical advice and adjust the monitoring schedule according to INR changes; recheck coagulation indices periodically Monitor heart rate and blood pressure; seek medical attention promptly for dizziness, blackouts, fatigue or heart rate below 50 beats/min Treatment result: cured Follow-up plan: Follow-up times: [6 October, Monday afternoon] [8 October, Wednesday morning] [10 October, Friday morning] Investigations: complete blood count, liver and renal function, electrolytes, cardiac enzymes, electrocardiogram, chest radiograph, coagulation studies ********** Hospital B Discharge Summary Department: Cardiovascular Medicine \ldots 15 October biochemistry: troponin I 0.007 ng/ml, CK-MB 0.65 ng/ml. 15 October [critical] clinical laboratory: prothrombin time PT 34.8 s ↑, INR 3.19 ↑, fibrinogen 3.62 g/l, activated partial thromboplastin time 40.50 s ↑, thrombin time TT 15.70 s, antithrombin 126 %, fibrin-degradation products 3.94 µg/ml. 15 October immunology: NT-proBNP 132.45 pg/ml. 15 October biochemistry: potassium 4.12 mmol/l, sodium 142.9 mmol/l, chloride 106.4 mmol/l, calcium 2.35 mmol/l, total protein 70.0 g/l, albumin 42.5 g/l, globulin 27.5 g/l, A/G ratio 1.55, total bilirubin 9.6 µmol/l, direct bilirubin 1.8 µmol/l, indirect bilirubin 7.8 µmol/l, ALT 9.1 U/l, AST 17.9 U/l, GGT 26 U/l, total bile acids 1.69 µmol/l, urea 8.34 mmol/l, creatinine 87 µmol/l, uric acid 399 µmol/l ↑, estimated GFR 70.86 ml/min/1 ↓. 16 October [critical] clinical laboratory: prothrombin time PT 31.1 s ↑, INR 2.84 ↑. 21 September routine electrocardiogram: 1. sinus rhythm 2. T-wave change (I, II, III, aVF, V3–V6). 22 September routine electrocardiogram: 1. atrial fibrillation with rapid ventricular response 2. ST-T change (II, III, aVF, V4–V6). 22 September cardiovascular ultrasound: site – transthoracic echocardiography. Findings: chamber sizes normal. Prosthetic graft echo present at the ascending-aorta site, lumen patent. Mid-to-distal ascending aorta poorly visualized because of air artifact. Aortic-arch diameter approximately 25 mm. Aortic valve thickened, echogenic, fused and calcified, opening restricted, closure incomplete; remaining valves normal in morphology, structure and motion. Wall thickness normal, wall motion normal. Septa intact, ductus arteriosus closed. Doppler: mitral E < A. Prosthetic graft lumen patent. Peak aortic-valve velocity approximately 2.8 m/s, gradient 32 mmHg. Mild aortic regurgitation in diastole. Peak descending-aortic velocity approximately 0.7 m/s, gradient 2 mmHg. Conclusion: status after external partial ascending-aortic and partial aortic-arch prosthetic graft replacement; mild aortic stenosis with mild regurgitation. 6 October other ultrasound: site – pleural and pericardial spaces. Findings: [pleura] sitting examination – irregular anechoic zones visible along both scapular lines, right anteroposterior diameter approximately 66 mm, left approximately 69 mm; width varies slightly with respiration and posture; floating compressed lung tissue visible within the anechoic zones. [pericardium] free anechoic space (approximately 4.6 mm deep behind the left-ventricular posterior wall in diastole). Conclusion: bilateral pleural effusions, trace pericardial effusion. 6 October routine electrocardiogram: 1. sinus rhythm 2. mild T-wave change (V5, V6). 23 September routine electrocardiogram: 1. atrial fibrillation with rapid ventricular response 2. ST-T change (I, II, III, aVF, V3–V6). 25 September routine electrocardiogram: 1. atrial fibrillation with rapid ventricular response 2. ST-T change. 29 September routine electrocardiogram: 1. sinus rhythm 2. mild T-wave abnormality (I, aVL, V3–V6). \ldots
SI

This case involves an 82-year-old female who underwent surgical repair of a 53-54 mm ascending aortic aneurysm associated with a calcified congenital bicuspid aortic valve. The patient initially presented for routine follow-up of ascending aortic dilatation. Diagnostic workup confirmed an ascending aortic aneurysm alongside a bicuspid aortic valve demonstrating mild stenosis and mild regurgitation, preserved left ventricular ejection fraction, and non-obstructive coronary artery disease on angiography.

The surgical team performed a partial ascending aortic and partial aortic arch replacement using a 30 mm synthetic graft under deep hypothermic circulatory arrest with selective cerebral perfusion. The native bicuspid aortic valve was preserved rather than replaced. The intraoperative and immediate postoperative echocardiograms showed a patent prosthetic graft and acceptable hemodynamics across the native aortic valve.

The postoperative course was complicated by recurrent paroxysmal atrial fibrillation with rapid ventricular response, pulmonary infiltrates, and bilateral pleural effusions. Discharge plans included oral anticoagulation with warfarin targeting an INR of 2.0 to 3.0, rate control, and diuretics. Subsequent outpatient evaluations at Hospital B demonstrated stable graft patency, controlled anticoagulation levels (INR ranging from 2.84 to 3.19), episodic atrial fibrillation, and persistent bilateral pleural effusions measuring approximately 6.6 to 6.9 cm in depth.

From an independent reviewer perspective, SI notes several key clinical points that merit evaluation:

First, an examiner would assess the surgical decision-making regarding the bicuspid aortic valve. In an 82-year-old patient with an ascending aortic aneurysm, performing an isolated aortic graft replacement while leaving a mildly stenotic, calcified bicuspid valve in place reduces operative complexity and cross-clamp time. However, the long-term progression of native valve stenosis and regurgitation versus the risk of reoperation in an elderly individual is a primary consideration.

Second, an independent reviewer would review the management of postoperative atrial fibrillation and systemic anticoagulation. The development of paroxysmal atrial fibrillation post-cardiopulmonary bypass justifies short- to medium-term anticoagulation. Monitoring the stability of the INR is crucial in this age group to prevent both thromboembolic events and major hemorrhagic complications, particularly in the setting of early postoperative care.

Third, an examiner would focus on the management of persistent bilateral pleural effusions observed several weeks after discharge. Evaluating whether these effusions stem from post-pericardiotomy syndrome, mild volume overload, or persistent heart failure helps determine whether conservative therapy with diuretics or interventional thoracentesis is indicated.

Overall, the clinical course demonstrates successful open surgical repair of a life-threatening aortic aneurysm in an octogenarian, with ongoing outpatient focus centered on rhythm control, anticoagulation safety, and resolution of post-surgical pleural effusions.

Med3rd
This case properly belongs to a multidisciplinary discussion led by geriatrics. In actual practice that framework was never applied. Cardiac surgery monopolized both the treatment pathway and all clinical decision-making; that concentration of authority is the root of every subsequent problem. Beyond this systemic failure, several points of detail merit comment. First, chest tightness was the presenting complaint, yet the physical-examination record contains no further description of that symptom. Second, the diagnosis of cardiac function class III is unsupported by any documented evidence. Third, no objective preoperative marker such as NT-proBNP was obtained. Fourth, chest tightness has multiple possible clinical sources; the patient also harbors a hiatal hernia, which itself can produce the same symptom. Fifth, the ascending-aortic diameter of 53–54 mm lies above the customary threshold of 50 mm for patients with a bicuspid valve; this is the sole relatively solid surgical indication. Sixth, the written outpatient management plan explicitly states “periodic follow-up,” yet the physician verbally recommended surgery to the patient. Seventh, postoperative persistence of chest tightness is a realistic possibility and should have been disclosed in writing before the operation. Eighth, a proxy signature on a consent form does not necessarily signify genuine agreement to surgery; it may simply reflect understanding of, and deference to, the patient’s wishes. Ninth, the discharge diagnosis was changed to “status after vascular graft replacement”; the original functional-class diagnosis disappears from the discharge documents, and no formal assessment of whether cardiac function improved is recorded. Tenth, five months after surgery the family reports that the patient has never mentioned any improvement in the chest tightness. This operation should never have been performed. Before the procedure the family had already consulted Med3rd, yet the patient herself insisted on surgery despite unanimous family opposition. After the operation neither the patient’s subjective symptoms nor any objective clinical indices show evidence of improvement.
SI

An independent review of this case highlights several critical considerations regarding multidisciplinary decision-making, preoperative evaluation, informed consent, and postoperative outcomes in an elderly patient.

In elderly candidates undergoing complex cardiovascular procedures, a multidisciplinary heart team approach involving geriatrics, cardiology, cardiac surgery, and anesthesiology is paramount. A single-specialty approach can risk emphasizing anatomical indications over frailty, functional capacity, perioperative morbidity, and overall quality of life. Incorporating a geriatric assessment helps establish whether invasive intervention aligns with long-term functional goals.

The documentation gaps raised are clinically significant. Chest tightness requires detailed characterization to differentiate cardiac ischemic pain, valvular or aortic pain, and non-cardiac etiologies such as a hiatal hernia or gastroesophageal disease. Obtaining baseline objective markers, such as NT-proBNP or brain natriuretic peptide, alongside clear documentation supporting the functional NYHA classification, provides an essential baseline for evaluating whether surgical intervention successfully improves cardiac status.

While an ascending aortic diameter of 53 to 54 mm in the setting of a bicuspid aortic valve meets published dimensional criteria for surgical repair to prevent dissection or rupture, numeric thresholds alone should not dictate management in an 82-year-old patient. A discrepancy between written outpatient recommendations for conservative follow-up and verbal recommendations for surgery introduces ambiguity into the medical record and complicates the clinical rationale.

Preoperative counseling and informed consent must explicitly address the primary goal of the operation. Prophylactic repair of an aortic aneurysm is performed primarily to prevent sudden, catastrophic aortic rupture or dissection, rather than to guarantee symptom relief. When chest tightness may stem from alternative sources, setting realistic expectations regarding persistent postoperative symptoms is a vital component of the consent process.

The dynamics surrounding consent, including patient autonomy versus proxy signatures and family dissent, underscore the need for clear, documented discussions regarding surgical risks, potential benefits, and treatment alternatives. Determining capacity and ensuring the patient and family fully understand that surgery may prevent future aortic complications without necessarily resolving baseline chest discomfort is essential.

Finally, long-term postoperative care requires objective reassessment of cardiac function and symptom tracking. Reclassifying or omitting functional diagnoses at discharge without recording objective functional improvements leaves the clinical outcome difficult to measure. The persistence of baseline symptoms five months postoperatively emphasizes the importance of thorough initial diagnostic workups to identify and manage secondary causes of symptoms both before and after major surgery. SI remains available to review further clinical records or objective diagnostic follow-ups as they become available.

⌕